§ 18.20.170. Section 802.1.9 Condensate and Evaporative Cooler Waste, added.  


Latest version.
  • International Plumbing Code, 2009 Edition, Section 802.1.9 Condensate and Evaporative Cooler Waste, is hereby added to read as follows:

    802.1.9 Condensate and Evaporative Cooler Waste. Waste from evaporative cooler's automatic water draining systems and condensate from air conditioner units, when approved by the building official, shall discharge into the building drainage system through an indirect waste line, except such waste may be directly connected to a lavatory tailpiece or to an approved accessible inlet on a bath tub overflow when the connection is located in an area controlled by the same person or entity controlling the space served by the evaporative cooler or discharged so that the effluent is used for watering landscaping or other vegetation.